超音波診断装置の性能と表示画像

Performance and its Influence to Display Image of Ultrasonic Diagnostic Equipment

井出 正男

Masao IDE

武蔵工業大学

Dept. of Electronics and Communication Engineering, Musashi Institute of Technology

キーワード :

 Ultrasonic diagnosis showed rapid development and has occupied significant position in the clinical diagnosis. Many kinds of diagnostic equipments have developed. Amongst development of pulse echo diagnostic equipment is remarkable. This paper reviews the relation between peformance of the equipment and display image in pulse echo diagnostic equipment.
 On basic characteristics or performances of the equipment such as overall sensitivity, resolution, gray scale characteristics, frame rate, viewing field, distortion of display image, artifacts etc., their primary factors and their influence to display image are described. Further, this paper refer to other factors which affect on the display image and insists that one must care these relations in case of reading the display images.